Cleanup use of Win32 START by using "" for title. No need for temp
authorBruce Momjian
Fri, 11 Jun 2004 16:36:31 +0000 (16:36 +0000)
committerBruce Momjian
Fri, 11 Jun 2004 16:36:31 +0000 (16:36 +0000)
batch files anymore.

src/bin/pg_ctl/pg_ctl.c

index 3755ca094aae2d83f2b2d23c2b3feb0e889e854c..8eb7777774a46dcdec9589258274669fcd439eee 100644 (file)
@@ -4,7 +4,7 @@
  *
  * Portions Copyright (c) 1996-2003, PostgreSQL Global Development Group
  *
- * $PostgreSQL: pgsql/src/bin/pg_ctl/pg_ctl.c,v 1.15 2004/06/11 04:17:21 momjian Exp $
+ * $PostgreSQL: pgsql/src/bin/pg_ctl/pg_ctl.c,v 1.16 2004/06/11 16:36:31 momjian Exp $
  *
  *-------------------------------------------------------------------------
  */
@@ -221,71 +221,33 @@ start_postmaster(void)
     * to pass everything to a shell to process them.
     */
    char        cmd[MAXPGPATH];
-   int         ret;
-   char        *pgexec = postgres_path;
    
-#ifdef WIN32
    /*
-    *  Win32 has a problem with the interaction between START and system().
-    *  There is no way to quote the executable name passed to START.
-    *  Therefore, we put the executable name in a temporary batch file
-    *  and run it via START.
+    *   Win32 needs START /B rather than "&".
+    *
+    *  Win32 has a problem with START and quoted executable names.
+    *  You must add a "" as the title at the beginning so you can quote
+    *  the executable name:
+    *      http://www.winnetmag.com/Article/ArticleID/14589/14589.html
+    *      http://dev.remotenetworktechnology.com/cmd/cmdfaq.htm
     */
-   char        tmp[MAXPGPATH] = "C:\\PG_CTL_XXXXXX", /* good location? */
-               bat[MAXPGPATH];
-   int         fd = mkstemp(tmp);
-
-   if (fd == -1)
-   {
-       fprintf(stderr, _("%s: cannot create batch file %s to start server: %s\n"),
-                       progname, tmp, strerror(errno));
-       exit(1);
-   }
-   write(fd, postgres_path, strlen(postgres_path));
-   write(fd, "\n", 1);
-   close(fd);
-
-   strcpy(bat, tmp);
-   strcat(bat, ".BAT");
-   pgexec = bat;
-   if (rename(tmp, bat) == -1)
-   {
-       fprintf(stderr, _("%s: cannot rename batch file %s to %s: %s\n"),
-                       progname, tmp, bat, strerror(errno));
-       unlink(tmp);
-       exit(1);
-   }
-#endif
-
    if (log_file != NULL)
-       /* Win32 needs START /B rather than "&" */
 #ifndef WIN32
        snprintf(cmd, MAXPGPATH, "%s\"%s\" %s < \"%s\" >> \"%s\" 2>&1 &%s",
 #else
-       snprintf(cmd, MAXPGPATH, "%sSTART /B %s %s < \"%s\" >> \"%s\" 2>&1%s",
+       snprintf(cmd, MAXPGPATH, "%sSTART /B \"\" \"%s\" %s < \"%s\" >> \"%s\" 2>&1%s",
 #endif
-                SYSTEMQUOTE, pgexec, post_opts, DEVNULL, log_file,
+                SYSTEMQUOTE, postgres_path, post_opts, DEVNULL, log_file,
                 SYSTEMQUOTE);
    else
 #ifndef WIN32
        snprintf(cmd, MAXPGPATH, "%s\"%s\" %s < \"%s\" 2>&1 &%s",
 #else
-       snprintf(cmd, MAXPGPATH, "%sSTART /B %s %s < \"%s\" 2>&1%s",
+       snprintf(cmd, MAXPGPATH, "%sSTART /B \"\" \"%s\" %s < \"%s\" 2>&1%s",
 #endif
-                SYSTEMQUOTE, pgexec, post_opts, DEVNULL, SYSTEMQUOTE);
+                SYSTEMQUOTE, postgres_path, post_opts, DEVNULL, SYSTEMQUOTE);
 
-   ret = system(cmd);
-
-#ifdef WIN32
-   /* We are unlinking it while it is running, but that should be OK */
-   if (unlink(bat))
-   {
-       fprintf(stderr, _("%s: cannot remove batch file %s: %s\n"),
-                       progname, bat, strerror(errno));
-       exit(1);
-   }
-#endif
-   return ret;
+   return system(cmd);
 }